60HZ 175KVA Cummins Diesel Power Generator Original Stamford Alternator
1. Engine / Alternator / Radiator unit on a common baseframe
2. Integral rubber anti- vibration mounts
3. Lead acid battery & industrial silencer
4. Exhaust flexible & industrial silencer
5. Standard factory load test and test report
6. 1 set of operating manuals
7. Controller panel: Smartgen 6120
8. With battery charger
9. 8 hours base fuel tank when 100% loading
150kva diesel power generator specification:
1. SPECIFICATIONS OF GEN-SET | ||
1.1 | Set Model | GP181DC |
1.2 | Prime at 50HZ, 40℃ ambient | 132KW 165KVA |
1.3 | Standby at 50HZ, 40℃ ambient | 145KW 181KVA |
1.4 | Rated Gen-set output | 230/400V 50Hz |
1.5 | Rated Relative humidity | ≤ 60 % |
1.6 | Dimension (L×W×H) | 3100×1120×1580mm |
1.7 | Weight | 1900kg |
1.8 | Fuel consumption 100% prime load | 26.5L/h |
1.9 | Total heat radiated to ambient | 76KW |
1.10 | Noise Level at 7m (Normal/Super) | 72dB |
1.11 | Structure of Gen-set |
The Gen-set adopt integrative structure, engine is fix on high strength steel basic frame, anti vibration instrument between the engine and basic frame, cooling fan have protecting cap, control cabinet and circuit breaker installed on Gen-set. |
1.12 | Control system (Optional) |
Basic control panel or Advanced control panel with automatically start-up function and other function. |
2. SPECIFICATIONS OF ENGINE | ||
2.1 | Engine Brand | Cummins |
2.2 | Engine Model | 6BTAA5.9-G12 |
2.3 | Governor/Class | Electrical |
2.4 | Cylinder NO. | 6 |
2.5 | Engine build | Line |
2.6 | Fuel spray pattern | PT direct injection |
2.7 | start-up method | 24V, electric |
2.8 | Aspiration |
Turbocharged /Aftercooled |
2.9 | Cooling mode |
Radiator cooled (enclose water) |
2.10 | Bore and stroke | 102×120mm |
2.11 | Compression ratio | 16.5:1 |
2.12 | Displacement | 5.9L |
2.13 | Engine Prime Power at 1500rpm | 140KWm |
2.14 | Engine Standby Power at 1500rpm | 154KWm |
2.15 | Battery capacity | 190A/hr |
2.16 | Starting/Min temperature | 7℃ |
2.17 | Lubrication oil capacity | 50L |
2.18 |
Coolant capacity - radiator and engine (40℃) |
91L |
2.19 | Exhaust temp - full load prime | 524℃ |
2.20 | Exhaust gas flow - full load prime | 4298m3/h |
2.21 | Exhaust gas back pressure max | 76mmHg |
2.22 | Air flow - radiator (40℃ ambient) | 10.6 m 3/s |
2.23 | Pusher fan head (duct allowance) 40℃ | 13mmH 2O |
2.24 | Air intake - engine- full load prime | 1555m3/h |
2.25 | Standard Air intake temp | 25℃ |
2.26 | Fuel type |
#0 Diesel (Natural temperature) |
2.27 | Filter system |
Adopt whole changeable lubricating oil, fuel filter and air filter |
2.28 | Exhaust system |
Adopt industrial high efficiency muffler and ripple pipe |
3. SPECIFICATIONS OF ALTENATOR | ||
3.1 | Alternator Model | STAMFORD UCI274K |
3.2 | Alternator Type | A.C. Synchronous |
3.3 | Rated Voltage | 230/400V |
3.4 | Rated Frequency | 50HZ |
3.5 | Rated speed | 1500 RPM |
3.6 | Voltage regulation mode | Auto |
3.7 | Alternator voltage regulation | ±0.5% |
3.8 | Exciting mode | Brushless self exciting |
3.9 | Power factor | 0.8 (lagging) |
3.10 | Phase & wires | 3 phase 12 wires |
3.11 | Rated currency | 548.5A |
3.12 | Efficiency | 0.937 |
3.13 | Insulation class | H |
3.14 | Protection class | IP23 |
There are many international brand generator controller for our cusomer 's choice,such as Smartgen, Deep sea, Compny, Harson and so on.
ATS: Upon detection of a mains(utility) failure the module automatically starts the generator set, once the mails (utility) power has been restored it instructs the generator set to stop.
Standard Supply Scope:
Generator set included: Diesel Engine, Brushless Alternator, Radiator, self-starting control panel, circuit breaker panel, Vibration damping pads, Hi-strength base frame
Accessories Included: industrial type silencer, flexible bellow, Elbow and Flanges, Starting Battery & battery charger, Battery switch with cables
Documents included: manual book, product qualified card
Optional supply scope:
1.ATS 2. SynchronizationSystem 3. External daily fuel tank 4. Silent Canopy 5. Trailer 6. Auto Fuel Pump 7. Fuel and Water Separator 8. Lub Oil Heater 9. Coolant Heater 10. Fuel Drain Pump
Advantages:
. We are a powerful and unity sales team:
. we are not just sales, but also professional engineers here to give you fast response of Technical support and power solutions.
90% of our sales team members are with more than 5 years of experience in the generator field.
. We have professional electrical & mechanical engineers, standby you, to solve the pre/after-sales service.
. We have strict Inspection dept. to make sure each genset is carefully test before leaving factory.
. With the experience and knowledge of Gensets, we are enthusiastic and patient, and can communicate with you easily and efficiently.
Sales Promises:
. Our company provides a full line of brand new and high quality products which are strictly tested before shipment
. Quality warranty is according to our standard conditions: One year or 1000 running hours
If have any questions, please contact us. Your inquiry would be appreciated.