Jarmogood morning rogers! today generator in action! quiet and high quality electricity! Tell greetings to everyone at your factory, good generator and Deutz motor! I've been in a hurry, farming with work, plowing! fields ready for spring 2020! it is snowing and after the frost, may Jarmo again in the field! regards, Jarmo!
-
Sam(Mali)Dear Karen, very happy to cooperate with you. The IVECO gensets are wonderful!
-
Adel Benhamadi(Lybia)مرحبا المبتسم، كيف حالك؟ لطيفة للعمل معكم ونحن شكرا جزيلا لك دعم على موقعنا على مولد الأعمال لك.
Three Phase AC Synchronous Stamford Alternators With AVR 12kw 15kva
Power(Prime/Standby) | 12kw 15kva | Frequency | 50/60hz |
---|---|---|---|
AVR | Brushless | Bearing | Single/Double |
Copper | 100% Copper | Protection | IP 22 Or IP23 |
Insulation | Class F/H | Warranty | One Year Or 1000hrs |
Voltage | 190-454v | ||
High Light | generator alternator,stamford alternators |
Three phase AC Synchronous brushless alternator with AVR 12kw 15kva
Alternator Model | UP184E |
Rated Power | 12kw 15kva |
Alternator Type | A.C. Synchronous |
Rated Voltage | 220-240V |
Rated Frequency | 50HZ |
Rated speed | 1500 RPM |
Voltage regulation mode | Auto |
Alternator voltage regulation | ±0.5% |
Exciting mode | Brushless self exciting |
Power factor | 0.8 (lagging) |
Phase & wires | 3 phase 12 wires |
Rated currency | 230.9A |
Efficiency | 0.923 |
Insulation class | H |
Protection class | IP23 |
Single load step to NFPA110 | 100% |
Standards | IEC34-1 |
Max. Ambient Temperature | 40℃ |
Min. Ambient Temperature | - 20℃ |
Max. altitude | 1000m |
Weight | 500kg |
Frame
All industrial standard is IP21,also IP23 is an option, but rates power will decrease 5%
Marine standard alternator is IP23,Air filter is an option, but rated power of the alternator will decrease 5% while it is installed.
Axis and Key
All of alternator rotors should pass balance test, whose vibrations are lower than the minimum of BS6861 P.1,G 2.5 two bearing alternator has a half-key testing balance
Terminal and terminal box
The three-field alternator had 12 leads brought out to the terminals in the terminal box. The terminals are put on the non drive end . The box is equipped with removable panels.
Voltage regulation
Voltage regulation refers to the change of voltage from no-load to full-load with power factor ranging from 0.8 to 1 and 3%s fluctuation of the speed of engine. Voltage is adjusted via potentiometer of AVR
Brushless alternators Photos: