Trailer Type Silent Generators 64kw 80kva Cummins Diesel Movable With Wheels
Common steel base frame, Damper, Exhaust silencer, Flexible pipe, Battery connecting wires, Rain Cover, Battery Charger, Operation manual and document
Optional Accessory
Circuit breaker, Starting Battery, Engine coolant and oil heater, Alternator space heater, Cooling for heat exchanger, Fuel-water separator,ATS & paralleling system, Soundproof Canopy and Moving Trailer.
Testing Items of Power Friend Genset:
1) Parts fault testing
2) Fue tank pressure testing
3) Bolt tightening torque testing
4) Painting thickness testing
5) Voltage bearing and insultion testing
6) Noise testing
7) Loading testing: All qualified generator sets are subjected to a comprehensive performance test which inclides 0% load, 25% load, 50% load, 75% load, 100% load and 110% load and to check, verify that all control systems, alarm and shut-own protection.
Cummins Model List:
Genset Model | Prime Power | Standby Power | Engine | ||||
KVA | KW | KVA | KW | Model | NO.Cylinder | Governor | |
PF-DC20 | 20 | 16 | 22 | 17.6 | 4B3.9-G1 | 4.L | M |
PF-DC25 | 25 | 20 | 27.5 | 22 | 4B3.9-G1 | 4.L | M |
PF-DC30 | 30 | 24 | 33 | 26.4 | 4BT3.9-G1 | 4.L | M |
PF-DC38 | 37.5 | 30 | 41.25 | 33 | 4BT3.9-G1 | 4.L | M |
PF-DC40 | 40 | 32 | 44 | 35.2 | 4BT3.9-G1 | 4.L | M |
PF-DC50 | 50 | 40 | 55 | 44 | 4BTA3.9-G2 | 4.L | E |
PF-DC60-1 | 60 | 48 | 66 | 52.8 | 4BTA3.9-G2 | 4.L | E |
PF-DC60-2 | 60 | 48 | 66 | 52.8 | 4BTA3.9-G11 | 4.L | E |
PF-DC63 | 62.5 | 50 | 68.75 | 55 | 4BTA3.9-G2 | 4.L | E |
PF-DC73 | 72.5 | 58 | 80 | 64 | 4BTA3.9-G11 | 4.L | E |
PF-DC80 | 80 | 64 | 88 | 70.4 | 6BT5.9-G2 | 6.L | E |
PF-DC100 | 100 | 80 | 110 | 88 | 6BT5.9-G2 | 6.L | E |
PF-DC113 | 112.5 | 90 | 123.75 | 99 | 6BTA5.9-G2 | 6.L | E |
PF-DC125 | 125 | 100 | 137.5 | 110 | 6BTAA5.9-G2 | 6.L | E |
PF-DC150-1 | 150 | 120 | 165 | 132 | 6BTAA5.9-G12 | 6.L | E |
PF-DC150-2 | 150 | 120 | 165 | 132 | 6CTA8.3-G2 | 6.L | E |
PF-DC188 | 187.5 | 150 | 206.25 | 165 | 6CTA8.3-G2 | 6.L | E |
PF-DC200 | 200 | 160 | 220 | 176 | 6CTAA8.3-G2 | 6.L | E |
PF-DC225 | 225 | 180 | 247.5 | 198 | 6LTAA8.9-G2 | 6.L | E |
PF-DC250-1 | 250 | 200 | 275 | 220 | 6LTAA8.9-G2 | 6.L | E |
PF-DC250-2 | 250 | 200 | 275 | 220 | 6LTAA8.9-G3 | 6.L | E |
PF-DC375 | 375 | 300 | 412.5 | 330 | 6ZTAA13-G3 | 6.L | E |
PF-DC400 | 400 | 320 | 440 | 352 | 6ZTAA13-G2 | 6.L | E |
PF-DC438 | 437.5 | 350 | 480 | 384 | 6ZTAA13-G2 | 6.L | E |
PF-DC450-1 | 450 | 360 | 495 | 396 | 6ZTAA13-G4 | 6.L | E |
PF-DC450-2 | 450 | 360 | 495 | 396 | QSZ13-G2 | 6.L | ECU |
PF-DC500 | 500 | 400 | 550 | 440 | QSZ13-G3 | 6.L | ECU |
Genset details:
Our advantages:
1) Each engine shall be tested at manufacturer’s workshop to certify the engine output according to present standard and fuel consumption in accordance with the site operating condition specified by purchaser on the specification datasheet.
2) All relevant information drawings pertinent to the testing and test procedure shall be transmitted to the purchaser in advance of the test date notification.
3) All accompanied documents are corresponding to the actual situation of generators, including the Qualified Certificate, Parameters and the Performance Index.