1000 Kw 1250kva 40ft Container Water Cooled Diesel Generator Silent Running Cummins Engine
PF-CC1100 Diesel Gen-set adopted Cummins engine, STAMFORD Alternator and the world famous brand controlling system, which has high quality and fit the standard system of GB/T2819, GB/T2820
GP1100CS DIESEL GEN-SET | ||
1. SPECIFICATIONS OF GEN-SET | ||
1.1 | Set Model | GP1100CS |
1.2 | Prime at 50HZ, 40℃ ambient | 800kW 1000KVA |
1.3 | Standby at 50HZ, 40℃ ambient | 880kW 1100KVA |
1.4 | Rated Gen-set output | 230/400V 50Hz |
1.5 | Rated Relative humidity | ≤ 60 % |
1.6 | Dimension (L×W×H) | 4500×1850×2600mm |
1.7 | Weight | 9050kg |
1.8 | Fuel consumption 100% prime load | 191L/h |
1.9 | Total heat radiated to ambient | 163KW |
1.10 | Structure of Gen-set | The Gen-set adopt integrative structure, engine is fix on high strength steel basic frame, anti vibration instrument between the engine and basic frame, cooling fan have protecting cap, control cabinet and circuit breaker installed on Gen-set. |
1.11 | Control system (Optional) | Basic control panel or Advanced control panel with automatically start-up function and other function. |
2. SPECIFICATIONS OF ENGINE | ||
2.1 | Engine Brand | Cummins |
2.2 | Engine Model | KTA38-G5 |
2.3 | Governor/Class | Electrical |
2.4 | Cylinder NO. | 12 |
2.5 | Engine build | Vee |
2.6 | Fuel spray pattern | PT direct injection |
2.7 | start-up method | 24V, electric |
2.8 | Aspiration | Turbocharged/Aftercooled |
2.9 | Cooling mode | Radiator cooled (enclose water) |
2.10 | Bore and stroke | 159×159mm |
2.11 | Compression ratio | 13.9:1 |
2.12 | Displacement | 38L |
2.13 | Engine Prime Power at 1500rpm | 880KWm |
2.14 | Engine Standby Power at 1500rpm | 970KWm |
2.15 | Battery capacity | 254A/hr |
2.16 | Starting/Min temperature | 7℃ |
2.17 | Lubrication oil capacity | 135L |
2.18 | Coolant capacity - radiator and engine (40℃) | 308L |
2.19 | Exhaust temp - full load prime | 499℃ |
2.20 | Exhaust gas flow - full load prime | 10663m3/h |
2.21 | Exhaust gas back pressure max | 76mmHg |
2.22 | Air flow - radiator (40℃ ambient) | 15 m 3/s |
2.23 | Pusher fan head (duct allowance) 40℃ | 13mmH 2O |
2.24 | Air intake - engine - full load prime | 4104m3/h |
2.25 | Standard Air intake temp | 25℃ |
2.26 | Fuel type | #0 Diesel (Natural temperature) |
2.27 | Filter system | Adopt whole changeable lubricating oil, fuel filter and air filter |
2.28 | Exhaust system | Adopt industrial high efficiency muffler and ripple pipe |
3. SPECIFICATIONS OF ALTENATOR | ||
3.1 | Alternator Model | Stamford/LVI6E |
3.2 | Alternator Type | A.C. Synchronous |
3.3 | Rated Voltage | 230/400V |
3.4 | Rated Frequency | 50HZ |
3.5 | Rated speed | 1500 RPM |
3.6 | Voltage regulation mode | Auto |
3.7 | Alternator voltage regulation | ±0.5% |
3.8 | Exciting mode | Brushless self exciting |
3.9 | Power factor | 0.8 (lagging) |
3.10 | Phase & wires | 3 phase 12 wires |
3.11 | Rated currency | 1443.4A |
3.12 | Efficiency | 0.942 |
3.13 | Insulation class | H |
3.14 | Protection class | IP23 |
3.15 | Single load step to NFPA110 | 100% |
3.16 | Standards | IEC34-1 |
3.17 | Max. Ambient Temperature | 40℃ |
3.18 | Min. Ambient Temperature | - 20℃ |
3.19 | Max. altitude | 1000m |
3.20 | Weight | 2190kg |
Product Show |
Our services |
Once receive any feedback of quality problem we will respond at the first time, and solve the problems within 24 hours.
Warraty period is one year or 1000 hours (depends on which occurs first ). If the failure is caused by turbine manufacturing defects, we will be responsible for problems caused by quality of production or raw material, except the damageable spare parts of genset caused by crew wearing parts, consumable parts for daily use, human error , negligence or failure of following the original maintenance manual provisions, etc.
We can professionally arrange experienced engineers to provide users with free training in our factory . Certainly , we also provide the paid training of customers’ site.
Company advantages |
we are not just sales, but also professional engineers here to give you fast response of Technical support and power solutions.
90% of our sales team members are with more than 5 years of experience in the generator field.
Our Workshop |
Major projects at home and abroad |
Trade shows |
Our company has participated in several exhibitions, such as Canton Fair(Guangzhou) and many foreign trade shows.
FAQ |
Q1: What is your warranty period?
A1: Our warranty period is 1 year or 1000 running hous, whichever comes first(Excep the damageable spare parts of genset caused by incorrect man-made operation).
Q2: Does your generator have global warranty?
A2: Yes. Global warranty service is available depending on the engines and alternators you choose. Please contact us for more details.
Q3: What is your payment terms?
A3: T/T 30% advance payment, the balance 70% shall be paid before shipment.
L/C Irrevocable L/C at sight.
Q4: What is your delivery time?
A4: Our standard delivery time is 20 to 30 days. If you have urgent demand, the delivery will be shorter depending on the requirements. If you have special requirements, the delivery will be longer.
Q5: Can the generators be customized?
A5: Yes. Our generators can be customized depending on customer's detailed requirements. We can supply generators for rental business, home use, inudstrial projects, army projects, power station, etc. The generators we supply is suitable for indoor and outdoor use, lower and high temperature environment.
Q6: Can you use our logo?
A6: Yes. For mass orders, we can use customer's logo instead of ours.